close Exit
Radwag - balances and scales store
dehaze search shopping_cart

Automatic Variable-Volume Pipettes

0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
This image is for reference only.
0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
close Exit
This image is for reference only.
0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0001

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
0,5 μl ÷ 10 μl
Systematic error
2,5% / 1,0%
Random error
1,5% / 0,8%
Tips
10 μl
2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
This image is for reference only.
2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
close Exit
This image is for reference only.
2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0002

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
2 μl ÷ 20 μl
Systematic error
3,0% / 0,9%
Random error
2,0% / 0,4%
Tips
300 μl
5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
This image is for reference only.
5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
close Exit
This image is for reference only.
5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0003

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
5 μl ÷ 50 μl
Systematic error
2,0% / 0,6%
Random error
2,0% / 0,3%
Tips
300 μl
10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
This image is for reference only.
10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
close Exit
This image is for reference only.
10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0004

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
10 μl ÷ 100 μl
Systematic error
3,0% / 0,8%
Random error
1,5% / 0,15%
Tips
300 μl
20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
This image is for reference only.
20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
close Exit
This image is for reference only.
20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0005

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
20 μl ÷ 200 μl
Systematic error
2,0% / 0,6%
Random error
0,8% / 0,15%
Tips
300 μl
100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
This image is for reference only.
100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
close Exit
This image is for reference only.
100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0006

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
100 μl ÷ 1000 μl
Systematic error
2,0% / 0,6%
Random error
0,7% / 0,2%
Tips
1000 μl
500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
This image is for reference only.
500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
close Exit
This image is for reference only.
500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Availability:
In stock
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipetteskeyboard_arrow_down
  • 0.5 μl ÷ 10 μl - RW8-101-20-9 Automatic Pipettes
  • 2 μl ÷ 20 μl - RW8-102-20-9 Automatic Pipettes
  • 5 μl ÷ 50 μl - RW8-103-20-9 Automatic Pipettes
  • 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes
  • 20 μl ÷ 200 μl - RW8-105-20-9 Automatic Pipettes
  • 100 μl ÷ 1000 μl - RW8-106-20-9 Automatic Pipettes
  • 500 μl ÷ 5000 μl - RW8-107-20-9 Automatic Pipettes
Options:
Selectkeyboard_arrow_down
  • None
  • Calibration Certificate
emailAsk about the product
Rating:
star star star star star
Code:
PA-203-0007

Overview


RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.

Features:
  • Large and readable display that is fully visible during pipetting;
  • Innovative soft grip preventing heat transfer to the pipette inside;
  • Low pressure required to use the pipette reduces the risk of RSI;
  • Simple click mechanism for changing the pipette volume;
  • Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure;
  • Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion;
  • Ultra UV resistance;
  • Convenient button for changing the tips;
  • Compatible with most of the tips available on the market.
2 years warranty
2 years warranty

Datasheet

Volume
500 μl ÷ 5000 μl
Systematic error
2,0% / 0,5%
Random error
0,6% / 0,15%
Tips
5000 μl