close Exit
Radwag - balances and scales store
dehaze search shopping_cart

Power Adapters

SYS-1544-2415-T3-HRP Power Adapter
This image is for reference only.
SYS-1544-2415-T3-HRP Power AdapterSYS-1544-2415-T3-HRP Power AdapterSYS-1544-2415-T3-HRP Power AdapterSYS-1544-2415-T3-HRP Power Adapter
close Exit
This image is for reference only.
SYS-1544-2415-T3-HRP Power AdapterSYS-1544-2415-T3-HRP Power AdapterSYS-1544-2415-T3-HRP Power AdapterSYS-1544-2415-T3-HRP Power Adapter
Availability:
Estimated shipping date :
To order
Price:
Individual pricing
Select
a variant:
SYS-1544-2415-T3-HRP Power Adapterkeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-015-0206

Overview


SYS-1544-2415-T3-HRP power supplier with hermetic connector for HRP, MWSH, MWLH
CE
CE
PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
This image is for reference only.
PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex ScalePM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
close Exit
This image is for reference only.
PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex ScalePM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
Availability:
In stock
Estimated shipping date :
To order
Price:
Individual pricing
Select
a variant:
PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scalekeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-004-0215

Overview


The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to power the HX5.EX indicator.
PM01.EX power supply comes in two designs:

  • PM01.EX-1: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to power the HRP.EX.
PM02.EX power supply comes in two designs:

  • PM02.EX-1-2: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
2 years warranty
2 years warranty
CE
CE

Datasheet

Protection class
IP66 / IP68
ATEX Certification
II 2G Ex eb mb [ib] IIC T4 Gb
II 2D Ex tb [ib] IIIC T70°C Db
Working in zones
1, 2 (gases); 21, 22 (dusts)
Power supply
100 – 240 V AC 50/60 Hz
Power consumption max.
15 W
Operating temperature
-20 ÷ +40 °C
Storage temperature
-20 ÷ +60 °C
Relative humidity
10% ÷ 85% RH no condensation
Housing
stainless steel
Device dimensions
216×174×64 mm
PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
This image is for reference only.
PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex ScalePM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
close Exit
This image is for reference only.
PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex ScalePM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
Availability:
In stock
Estimated shipping date :
To order
Price:
Individual pricing
Select
a variant:
PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scalekeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-004-0203

Overview


The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to power the HX5.EX indicator.
PM01.EX power supply comes in two designs:

  • PM01.EX-1: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to power the HRP.EX.
PM02.EX power supply comes in two designs:

  • PM02.EX-1-2: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
2 years warranty
2 years warranty
CE
CE

Datasheet

Protection class
IP66 / IP68
ATEX Certification
II (2)G [Ex ib Gb] IIC
II (2)D [Ex ib Db] IIIC
Working in zones
-
Power supply
100 – 240 V AC 50/60 Hz
Power consumption max.
15 W
Operating temperature
-20 ÷ +40 °C
Storage temperature
-20 ÷ +60 °C
Relative humidity
10% ÷ 85% RH no condensation
Housing
stainless steel
Device dimensions
216×174×64 mm
PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
This image is for reference only.
PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex ScalePM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
close Exit
This image is for reference only.
PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex ScalePM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
Availability:
In stock
Estimated shipping date :
To order
Price:
Individual pricing
Select
a variant:
PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scalekeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-004-0257

Overview


The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to power the HRP.EX.
PM02.EX power supply comes in two designs:

  • PM02.EX-1-2: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to power the HX5.EX indicator.
PM01.EX power supply comes in two designs:

  • PM01.EX-1: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
2 years warranty
2 years warranty
CE
CE

Datasheet

Protection class
IP66 / IP68
ATEX Certification
II 2G Ex eb mb [ib] IIC T4 Gb
II 2D Ex tb [ib] IIIC T70°C Db
Working in zones
1, 2 (gases); 21, 22 (dusts)
Power supply
100 – 240 V AC 50/60 Hz
Power consumption max.
15 W
Operating temperature
-20 ÷ +40 °C
Storage temperature
-20 ÷ +60 °C
Relative humidity
10% ÷ 85% RH no condensation
Housing
stainless steel
Device dimensions
216×174×64 mm
PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
This image is for reference only.
PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex ScalePM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
close Exit
This image is for reference only.
PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex ScalePM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
Availability:
In stock
Estimated shipping date :
To order
Price:
Individual pricing
Select
a variant:
PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scalekeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-004-0258

Overview


The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to power the HRP.EX.
PM02.EX power supply comes in two designs:

  • PM02.EX-1-2: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to power the HX5.EX indicator.
PM01.EX power supply comes in two designs:

  • PM01.EX-1: power supply intended for operation in hazardous area:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
  • PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
    • Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as  explosion group IIC, IIB and IIA and as temperature  class T1, T2, T3, T4.
    • Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
2 years warranty
2 years warranty
CE
CE

Datasheet

Protection class
IP66 / IP68
ATEX Certification
II (2)G [Ex ib Gb] IIC
II (2)D [Ex ib Db] IIIC
Working in zones
-
Power supply
100 – 240 V AC 50/60 Hz
Power consumption max.
15 W
Operating temperature
-20 ÷ +40 °C
Storage temperature
-20 ÷ +60 °C
Relative humidity
10% ÷ 85% RH no condensation
Housing
stainless steel
Device dimensions
216×174×64 mm
ZR-03/1 Power Adapter
This image is for reference only.
ZR-03/1 Power AdapterZR-03/1 Power AdapterZR-03/1 Power AdapterZR-03/1 Power AdapterZR-03/1 Power Adapter
close Exit
This image is for reference only.
ZR-03/1 Power AdapterZR-03/1 Power AdapterZR-03/1 Power AdapterZR-03/1 Power AdapterZR-03/1 Power Adapter
Availability:
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
ZR-03/1 Power Adapterkeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-015-0319

Overview


The ZR-03/1 buffer power supply is a cutting-edge device with fast charging technology. It serves as a battery for balances, scales, and accessories.

 

The ZR-03/1 set includes:

  • voltage converter with a cable (for scale connection) and with appropriate terminals,
  • dedicated power bank.

 

Voltage Converter

The voltage converter is equipped with a diode indicating the operating status:

  • a low brightness level indicates the initialisation of the connection between the power supply and the receiver,

·         the maximum brightness of the LED indicates that the balance or scale is being supplied with power.

The voltage converter should be connected to the USB type A socket on the power bank.

 

Power Bank

To charge the power bank, simply use any mobile phone charger.
The optimal solution is a charger with a fast charging function to speed up the process.

 

The most important advantages of the power bank being a part of the ZR-03/1 set are considered to be:

  • significantly long operating time without charging,
  • display indicating the charging status,
  • power supplying of up to 3 devices,
  • high-quality components that guarantee reliability and safety (world-class chips, trouble-free batteries, state-of-the-art circuitry, unique design and robust multilayer coating),
  • 7 levels of protection: against overcharge, discharge, overvoltage, overheating, overcurrent, short circuit, and electromagnetic field.

In addition, the power bank has passed a number of safety tests, received numerous certificates, and complies with airline standards.

 

Average supply time

5Y series: 8 h

4Y series: 10 h

X2 series: 14 h

C32 series: 12 h

R2 series: 24 h

WLC series: 18 h

WTC series: 24 h

C315 series: 24 h

 

CE
CE

Datasheet

Power supply
Micro USB: DC 5V/2A, 9V/2A
Type-C: DC 5V/3A, 9V/2.22A, 12V/1,5A
Device dimensions
153×69×42 mm
Packaging dimensions
230×190×80 mm
Net weight
645 g
Gross weight
900 g
ZR-03/2 Power Adapter
This image is for reference only.
ZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power Adapter
close Exit
This image is for reference only.
ZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power AdapterZR-03/2 Power Adapter
Availability:
Estimated shipping date :
Price:
Individual pricing
Select
a variant:
ZR-03/2 Power Adapterkeyboard_arrow_down
  • SYS-1544-2415-T3-HRP Power Adapter
  • PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale
  • ZR-03/1 Power Adapter
  • ZR-03/2 Power Adapter
emailAsk about the product
Rating:
star star star star star
Code:
WX-015-0327

Overview


The ZR-03/2 buffer power supply is a cutting-edge device with fast charging technology. It serves as a battery for balances, scales, and accessories.

 

The ZR-03/2 set includes:

  • voltage converter with a cable (for scale connection) and with appropriate terminals,
  • dedicated power bank.

 

Voltage Converter

The voltage converter is equipped with a diode indicating the operating status:

  • a low brightness level indicates the initialisation of the connection between the power supply and the receiver,

·         the maximum brightness of the LED indicates that the balance or scale is being supplied with power.

The voltage converter should be connected to the USB type A socket on the power bank.

 

Power Bank

To charge the power bank, simply use any mobile phone charger.
The optimal solution is a charger with a fast charging function to speed up the process.

 

The most important advantages of the power bank being a part of the ZR-03/2 set are considered to be:

  • significantly long operating time without charging,
  • display indicating the charging status,
  • power supplying of up to 3 devices,
  • high-quality components that guarantee reliability and safety (world-class chips, trouble-free batteries, state-of-the-art circuitry, unique design and robust multilayer coating),
  • 7 levels of protection: against overcharge, discharge, overvoltage, overheating, overcurrent, short circuit, and electromagnetic field.

In addition, the power bank has passed a number of safety tests, received numerous certificates, and complies with airline standards.

 

Average working time: up to 20 h. The working time depends on the number of connected peripherals and the power consumed from the terminal.

 

 

CE
CE

Datasheet

Power supply
Micro USB: DC 5V/2A, 9V/2A
Type-C: DC 5V/3A, 9V/2.22A, 12V/1,5A
Operation time on batteries
max 20h
Device dimensions
153×69×42 mm
Packaging dimensions
230×190×80 mm
Net weight
645 g
Gross weight
900 g